Helifix Repairs To A Property Suffering From Masonry Cracking
Defect
We were approached by a residential client requiring a repair scheme where they had noticed cracking to various areas of the front elevation. » Read More
Defect
We were approached by a residential client requiring a repair scheme where they had noticed cracking to various areas of the front elevation. » Read More
Defect
We were contacted by the owner of a four storey residential property; to provide a repair scheme for the rear elevation, where cracking and sagging had occurred. » Read More
Defect
We were approached by a local builder who was working on a residential property. He required a repair scheme and quotation where he noticed cracking and outward movement to the first floor bay window.
Our local surveyor visited the property the next day to carry out a survey. Whilst at the property our surveyor discussed with the builder the best course of action. » Read More
DEFECT
We were contacted by a residential client who noticed cracking had occurred to the porch and lounge. Our local surveyor visited the property the next day and we provided the client with a full specification, including drawings and a detailed quotation.
DEFECT
ASRS were contacted by a residential client requiring a specification to repair the defective masonry throughout their property. We specified the installation of the Helifix system to restore the structural integrity of the masonry where cracking, bowing and delamination had occurred. The property was also suffering from the poorly constructed masonry.
ASRS Ltd were contacted to provide a specification for structural stabilisation works to a bungalow which was suffering from downward movement and cracked masonry. » Read More
ASRS Ltd were contacted by a residential customer who required a specification to restore the structural integrity of the masonry where cracking to the internal block work had occurred.
The two storey property was constructed with what was thought to be a weak batch of block work with a strong mortar mix.
ASRS Ltd were contacted to provide a specification to stabilise a retaining wall at a large commercial building, where cracking and leaning had occurred. We specified the installation of Platipus ground anchors in conjunction with the Helibeam system to reinstate the structural integrity of the long section and flank section of the wall. » Read More
ASRS Ltd were contacted by a Chartered Building Company who required structural stabilisation repairs to a secure Royal Navy Air Station. Their requirement was to use a long standing company with a successful track record of working on secure sites.
The building had suffered vertical cracking to two elevations due to the window reveals being reduced in size. » Read More
ASRS were contacted by a consulting structural engineer who required a specification and quotation for structural stabilisation works to the front elevation of a residential property. Prior to providing the quotation, one of our many Helifix approved surveyors carried out a survey at the property. Whilst visiting the property it became apparent that we needed to restore the structural integrity of the masonry where delamination and bowing had occurred. » Read More